Loading docs/source/CITests.rt +11 −14 Original line number Diff line number Diff line Loading @@ -22,17 +22,14 @@ with the following notations: Below Ng = number of grids, Npa = number of particles, Np = number of MPI ranks. "Auto" means the particles were generated automatically with the random number generator; if "Auto" is not specified the particle data were read in from "particle_input.dat" These first tests have both fluid and particles and are run in rectangular geometries; all tests except DEM06 use drag type "BVK2". All the FLD cases are fluid-only. All the DEM cases are particle-only except for DEM06 and DEM07 which are fluid and particles; these both use the "BVK2" drag type. In all cases the particle data were read in from "particle_input.dat" "NSW" means "No Slip Wall" and "Per" is "periodic." "MI/PO" refers to Mass Inflow at the low end of the domain and Pressure Outflow at the high end, "PI/PO" refers to Pressure Inflow at the low end of the domain and Pressure Outflow at the high end, This third set of tests is particles-only in rectangular geometries. "MI/PO" refers to Mass Inflow at the low end of the domain and Pressure Outflow at the high end. "PI/PO" refers to Pressure Inflow at the low end of the domain and Pressure Outflow at the high end. +-------------------+----+-------+------+--------+----+----+----------------------+ | Test | nx | bc_x | EB | Npa | Ng | Np | What does this test? | Loading @@ -40,15 +37,15 @@ This third set of tests is particles-only in rectangular geometries. | | nz | bc_z | | | | | | +===================+====+=======+======+========+====+====+======================+ | FLD01-x:SGS | 8 | Per | None | 0 | 1 | 1 | | | MGS | 4 | NSW | | | 2 | | | | MGS | 4 | NSW | | | 2 | 1 | | | MGP | 4 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | FLD02-x:SGS | 80 | MI/PO | None | 0 | 1 | 1 | | | MGS | 16 | NSW | | | 40 | | | | MGS | 16 | NSW | | | 40 | 1 | | | MGP | 16 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | FLD03-x:SGS | 8 | PI/PO | None | 0 | 1 | 1 | | | MGS | 8 | NSW | | | 4 | | | | MGS | 8 | NSW | | | 4 | 1 | | | MGP | 4 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM01:SGS | 2 | NSW | None | 1 | 1 | 1 | Particle only | Loading @@ -72,10 +69,10 @@ This third set of tests is particles-only in rectangular geometries. | | 5 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM06-x:SGS | 50 | NSW | None | 1 | 1 | 1 | | | MGS | 5 | NSW | | | 10 | 4 | | | MGS | 5 | NSW | | | 10 | 1 | | | MGP | 5 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM07-x | 20 | Per | None | 1222 | 1 | 1 | | | MGS | 20 | Per | | | 8 | | | | MGS | 20 | Per | | | 8 | 1 | | | MGP | 20 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ Loading
docs/source/CITests.rt +11 −14 Original line number Diff line number Diff line Loading @@ -22,17 +22,14 @@ with the following notations: Below Ng = number of grids, Npa = number of particles, Np = number of MPI ranks. "Auto" means the particles were generated automatically with the random number generator; if "Auto" is not specified the particle data were read in from "particle_input.dat" These first tests have both fluid and particles and are run in rectangular geometries; all tests except DEM06 use drag type "BVK2". All the FLD cases are fluid-only. All the DEM cases are particle-only except for DEM06 and DEM07 which are fluid and particles; these both use the "BVK2" drag type. In all cases the particle data were read in from "particle_input.dat" "NSW" means "No Slip Wall" and "Per" is "periodic." "MI/PO" refers to Mass Inflow at the low end of the domain and Pressure Outflow at the high end, "PI/PO" refers to Pressure Inflow at the low end of the domain and Pressure Outflow at the high end, This third set of tests is particles-only in rectangular geometries. "MI/PO" refers to Mass Inflow at the low end of the domain and Pressure Outflow at the high end. "PI/PO" refers to Pressure Inflow at the low end of the domain and Pressure Outflow at the high end. +-------------------+----+-------+------+--------+----+----+----------------------+ | Test | nx | bc_x | EB | Npa | Ng | Np | What does this test? | Loading @@ -40,15 +37,15 @@ This third set of tests is particles-only in rectangular geometries. | | nz | bc_z | | | | | | +===================+====+=======+======+========+====+====+======================+ | FLD01-x:SGS | 8 | Per | None | 0 | 1 | 1 | | | MGS | 4 | NSW | | | 2 | | | | MGS | 4 | NSW | | | 2 | 1 | | | MGP | 4 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | FLD02-x:SGS | 80 | MI/PO | None | 0 | 1 | 1 | | | MGS | 16 | NSW | | | 40 | | | | MGS | 16 | NSW | | | 40 | 1 | | | MGP | 16 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | FLD03-x:SGS | 8 | PI/PO | None | 0 | 1 | 1 | | | MGS | 8 | NSW | | | 4 | | | | MGS | 8 | NSW | | | 4 | 1 | | | MGP | 4 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM01:SGS | 2 | NSW | None | 1 | 1 | 1 | Particle only | Loading @@ -72,10 +69,10 @@ This third set of tests is particles-only in rectangular geometries. | | 5 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM06-x:SGS | 50 | NSW | None | 1 | 1 | 1 | | | MGS | 5 | NSW | | | 10 | 4 | | | MGS | 5 | NSW | | | 10 | 1 | | | MGP | 5 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM07-x | 20 | Per | None | 1222 | 1 | 1 | | | MGS | 20 | Per | | | 8 | | | | MGS | 20 | Per | | | 8 | 1 | | | MGP | 20 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+