Loading docs/source/NightlyTests.rst +14 −5 Original line number Diff line number Diff line Loading @@ -14,7 +14,7 @@ Below Ng = number of grids, Npa = number of particles, Np = number of MPI ranks. "Auto" means the particles were generated automatically with the random number generator; if "Auto" is not specified the particle data were read in from "particle_input.dat" All of these tests use drag type "BVK2". These first tests have both fluid and particles; they all use drag type "BVK2". +-------------------+----+-------+------+--------+----+----+----------------------+ | Test | nx | bc_x | EB | Npa | Ng | Np | What does this test? | Loading Loading @@ -65,6 +65,19 @@ All of these tests use drag type "BVK2". | Size0008 | 10 | IG | | Auto | | | with periodic | | | 10 | IG | | | | | parallel | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM06 | 5 | Per | None | 1 | 10 | 4 | | | z multiple | 5 | Per | | | | | | | | 50 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ This second set of tests is particles-only. +-------------------+----+-------+------+--------+----+----+----------------------+ | Test | nx | bc_x | EB | Npa | Ng | Np | What does this test? | | | ny | bc_y | | | | | | | | nz | bc_z | | | | | | +===================+====+=======+======+========+====+====+======================+ | DEM01 | 4 | NSW | None | 1 | 1 | 1 | Particle only | | x single | 4 | NSW | | | | | | | | 4 | NSW | | | | | | Loading @@ -81,7 +94,3 @@ All of these tests use drag type "BVK2". | z single | 2 | Per | | | | | | | | 5 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM06 | 5 | Per | None | 1 | 10 | 4 | | | z multiple | 5 | Per | | | | | | | | 50 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ Loading
docs/source/NightlyTests.rst +14 −5 Original line number Diff line number Diff line Loading @@ -14,7 +14,7 @@ Below Ng = number of grids, Npa = number of particles, Np = number of MPI ranks. "Auto" means the particles were generated automatically with the random number generator; if "Auto" is not specified the particle data were read in from "particle_input.dat" All of these tests use drag type "BVK2". These first tests have both fluid and particles; they all use drag type "BVK2". +-------------------+----+-------+------+--------+----+----+----------------------+ | Test | nx | bc_x | EB | Npa | Ng | Np | What does this test? | Loading Loading @@ -65,6 +65,19 @@ All of these tests use drag type "BVK2". | Size0008 | 10 | IG | | Auto | | | with periodic | | | 10 | IG | | | | | parallel | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM06 | 5 | Per | None | 1 | 10 | 4 | | | z multiple | 5 | Per | | | | | | | | 50 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ This second set of tests is particles-only. +-------------------+----+-------+------+--------+----+----+----------------------+ | Test | nx | bc_x | EB | Npa | Ng | Np | What does this test? | | | ny | bc_y | | | | | | | | nz | bc_z | | | | | | +===================+====+=======+======+========+====+====+======================+ | DEM01 | 4 | NSW | None | 1 | 1 | 1 | Particle only | | x single | 4 | NSW | | | | | | | | 4 | NSW | | | | | | Loading @@ -81,7 +94,3 @@ All of these tests use drag type "BVK2". | z single | 2 | Per | | | | | | | | 5 | Per | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+ | DEM06 | 5 | Per | None | 1 | 10 | 4 | | | z multiple | 5 | Per | | | | | | | | 50 | NSW | | | | | | +-------------------+----+-------+------+--------+----+----+----------------------+