Commit 3847f713 authored by Ann Almgren's avatar Ann Almgren
Browse files

Update info on time stepping

parent 262732d3
No related branches found
No related tags found
No related merge requests found
......@@ -69,18 +69,33 @@ That is determined by the following calculation:
2) In a pure fluid case, there are two options:
* If you want to fix the dt, simply set :cpp:`mfix.fixed_dt = XXX` and the fluid time
step will always be that number. [SHOULD WE ABORT IF YOU ALSO SET CFL? OR SPECIFY
THAT FIXED_DT OVERRIDES CFL?]
step will always be that number.
* If you want to let the code determine the appropriate time step using the advective CFL
condition, then set :cpp:`mfix.cfl = 0.5` for example, and the fluid time step will
condition, then set :cpp:`mfix.cfl = 0.7` for example, and the fluid time step will
be computed to be dt = 0.5 * dx / max(vel).
Note that these choices apply to steady state calculations as well as unsteady runs.
* If dt as computed in the compute_dt routine is smaller than the user-specified
```mfix.dt_min``` then the code will abort:
.. highlight:: c++
::
amrex::Abort::0::"Current dt is smaller than dt_min !!!
* If dt as computed in the compute_dt routine is larger than the user-specified
```mfix.dt_max``` then dt will be set to the minimum of its computed value and dt_max
* If dt as computed in the compute_dt routine is larger than the user-specified
* Note that the cfl defaults to 0.5 so it does not have to be set in the inputs file. If neither
:cpp:`mfix.cfl` nor :cpp:`fixed_dt` is set, then the default will be the second option here.
If :cpp:`mfix.fixed_dt` is set, then it will override the cfl option whether
:cpp:`mfix.cfl` is set or not in the inputs file.
These options apply to steady state calculations as well as unsteady runs.
3) In a coupled particle-fluid case, dt is set as in the pure-fluid case. In this case
the particle time step is first computed as in the particle-only case, then is adjusted
so that an integral number of particle steps fit into a single fluid time step.
[HOW ARE DT_MIN AND DT_MAX USED???]