5. MFIX-PIC Code Verification Test Cases

The contents in this section are derived from the TRS report on MFiX-PIC V&V [32] published in 2020. The test cases presented in this chapter are summarized in Table 5.1. Under verification (PIC01-PIC05), the results from MFiX-PIC are compared with exact or analytical solutions, while experimental results are used for benchmarking under validation (PIC06 and PIC07).

Table 5.1 Summary of MFiX-DEM tests by feature.

01

02

03

04

05

06

07

Frequency†

C

C

C

C

C

C

C

Reference Dataset‡

A

A

A

A

A

P

P

Dimension

3D

3D

3D

3D

3D

3D

3D

Coupled

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

Momentum

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

\({\checkmark}\)

Thermal Energy

\({\checkmark}\)

Particle Mass

\({\checkmark}\)

Species Mass

\({\checkmark}\)

Distributed Memory

\({\checkmark}\)

Shared Memory

† C-Incorporated into the continuous integration server; M-Monthly; Q-Quarterly; X-Manual; D-Disabled

‡ A-Analytical solution; P-Published benchmark data; R-Regression data from previous code versions