5. MFIX-PIC Code Verification Test Cases¶
The contents in this section are derived from the TRS report on MFiX-PIC V&V [32] published in 2020. The test cases presented in this chapter are summarized in Table 5.1. Under verification (PIC01-PIC05), the results from MFiX-PIC are compared with exact or analytical solutions, while experimental results are used for benchmarking under validation (PIC06 and PIC07).
01 |
02 |
03 |
04 |
05 |
06 |
07 |
|
---|---|---|---|---|---|---|---|
Frequency† |
C |
C |
C |
C |
C |
C |
C |
Reference Dataset‡ |
A |
A |
A |
A |
A |
P |
P |
Dimension |
3D |
3D |
3D |
3D |
3D |
3D |
3D |
Coupled |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
||
Momentum |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
\({\checkmark}\) |
|
Thermal Energy |
\({\checkmark}\) |
||||||
Particle Mass |
\({\checkmark}\) |
||||||
Species Mass |
\({\checkmark}\) |
||||||
Distributed Memory |
\({\checkmark}\) |
||||||
Shared Memory |
† C-Incorporated into the continuous integration server; M-Monthly; Q-Quarterly; X-Manual; D-Disabled
‡ A-Analytical solution; P-Published benchmark data; R-Regression data from previous code versions
- 5.1. PIC01: Terminal velocity
- 5.2. PIC02: Advection in time varying flow field – velocity interpolation
- 5.3. PIC03: Advection in time varying flow field – parcel volume deposition
- 5.4. PIC04: Particle-Settling in Fluid
- 5.5. PIC05: Evaporation
- 5.6. PIC06: Rayleigh-Taylor Instability
- 5.7. PIC07: Minimum fluidization